- Bus Interface: RS485
- Operating Voltage: DC 12V
- Standby current: 13MA
- Channels: 16
- Rail: DIN35
¿É¼ÇÁ¤º¸[(200004763)Only Board][(200004182)with Din Rail Box]
Product Name: DC 12V DIN35 C45 Rail Box 16 Channel RS485 Relay Module Modbus RTU UART Control Switch Board for PLC PTZ Camera Motor LED
Package inlcuded:
1PCS DC 12V 16Ch DIN35 Rail RS485 Modbus RTU Relay Board
Description:
1: DC 12V power supply
2: Standby current (all relays closed) 13MA, 1 relay open 41MA, 2 relays open 69MA, 3 relays open 95MA,4 relays open 122MA,5 relays open 148MA,6 relays open 174MA, 7 relays open 198MA,8 relays open 225MA.etc
3: ``open`` ``close`` ``Momentary`` ``Self-locking`` ``Interlock`` ``Delay`` 6 Commands
4: Two instruction-control mode : MODBUS RTU command and AT command
5: Under the ``Delay`` command ,the maximum delay is 255 seconds;
Under the AT command ,the maximum delay is 9999 seconds
6 MODBUS commands can be made serial HyperTerminal (serial assistant) OR ``Modbus Poll`` Enter; AT commands can be made serial HyperTerminal (serial assistant) Enter;
7 Under the MODBUS command mode, it can support up to 64 devices in parallel
8 The default baud rate is 9600BPS. The baud rate can be selected through jumpers: 2400 4800 9600 19200BPS
9 Size: 180 * 72 * 20mm(Only PCB Board);184 * 88* 42mm(with Din Rail Box)
10 Weight: 230g(Only PCB Board);358g(with Din Rail Box)
11 Maximum load: 10A / 250VAC, 10A / 125VAC, 10A / 30VDC, 10A / 28VDC, 10A / 12VDC
For more information, please contact me
DIN rail Box parameters: Product model: UM72 Color: green Width: suitable for PCB board width UM72(72mm) Insulation grade: flame-retardant VO grade Backplane length: suitable for 180 mm PCB boards Net weight: 128g Installation: DIN35 and C45 rail
Application
PLC expansion board Smart Home,Home Automation ,Wiser Home;
PTZ CCTV Camera
Security Monitoring
Identification system;
Motor FW & BW Automatic curtain control
Typical applications:
1 When controlling a module, you can use the MODUBS RTU instruction or the AT instruction. In AT command mode, the dial switch (slave address) is invalid and can only control one module at a time.
MODBUS RTU command mode (HEX), you can control a variety of ways: Serial Hyper Terminal Control (need to manually add the CRC), Modbus Poll software control (software automatically add the CRC), PLC or MCU process control
1 DC 12V control circuit,Wiring diagram below. ``LOAD`` may be camera,LED lights, fans, motors and other DC 12V equipment
2 DC 1-110V OR AC 85-265V control circuit,Wiring diagram below(Note:If not DC 12V load, need another DC 12V power supply). ``LOAD`` may be LED lights, fans, motors Lights, fluorescent lights, solar water heaters and other DC AC equipmen
Test Software(We offer a demo video):
Serial HyperTerminal:
Modbus Poll
|
|
|
|
|