Working principle:
A thermosensitive element is installed at the mixing outlet of the constant temperature water mixing valve, which uses the characteristics of the thermosensitive element to drive the valve core in the valve body to move, block or open the inlet of hot and cold water. When the hot water is opened while the cold water is blocked, no matter how the temperature and pressure of the cold and hot water inlet change, the proportion of the cold and hot water entering the outlet will also change, so that the temperature of the outlet will remain constant all the time. The temperature regulating knob can be set arbitrarily in the range of the specified temperature of the product, and the constant temperature water mixing valve will automatically maintain the temperature of the outlet.
Product characteristics:
1. Work pressure: 0.05 Mpa-1 Mpa.
2. Ideal pressure: 0.1Mpa-0.5Mpa, more than 0.5MPa to install pressure relief valve.
3. Standard pressure: dynamic pressure 0.3 +0.02Mpa.
4. Cold water supply temperature: 4-29 degrees C, hot water supply temperature: 55-85 degrees C, the recommended normal use temperature is 60-70 degrees C.
5. Temperature range of constant temperature effluent: 20-50 C.
6. Set the temperature of safety button: 38 C.
7. Safety and anti-scalding: When cold water is unexpectedly out of supply, the flow rate of mixed effluent decreases rapidly from zero to zero.
8. Accurate temperature: Set the required temperature first, and you can reach the required temperature within 5 seconds after the water is discharged. The temperature fluctuation of the water is within (+) 1 C.
9. The outlet temperature is stable: when the inlet temperature remains unchanged, the pressure of cold and hot water varies arbitrarily by 50%, and the outlet temperature fluctuates within (+2). When the inlet pressure remains unchanged, the temperature of hot water supply rises from 60 (+5 C/min), and the outlet temperature fluctuates within (+2).
Package include:
1x value