1.4.2.6 Main Page Display Style Setting
Main interface display style setting operation video:
You can press SHIFT + MENU to enter the system setting menu, and then press the right button to enter the main page style setting menu as shown above. Press ENTER and then use direction button to set classic style or curve style. The pattern in red is the style being?chosen.?Press the encoder potentiometer?to return and save the?settings.?The classic style is the system default style, it shows the voltage, current and power?in large font. The curve style is as shown above, the color of the three curves corresponds to the output voltage, current and power. D is the scale of the ordinate, Press?"ENTER"?to start or pause the curve, and rotate the?encoder potentiometer to scale the ordinate of the curve.
1.4.2.7?Storage Data Setting
Data group setting in manual operation video:
You can press SHIFT + MENU to enter the system setting menu, and then press the right button twice to enter the data storage setting menu as shown below, press ENTER to enter the setting menu, the icon in red is the chosen data group, press the direction button to select data group number. Press "I-SET"?button to set the storage output current value, then rotate the encoder potentiometer the adjust the output value, press the direction button to move the cursor. You can also set the value with keypad, press ENTER to confirm. If you set the wrong value, you can press the encoder potentiometer to cancel. Press "V-SET"?button to set the storage output voltage value, the operation method is similar to storage output current setting.
Press?"SHIFT"+ "I-SET"?button or?"SHIFT"+ "V-SET"?button to set the storage over current protection/ storage over voltage protection value. The operation method is similar to storage output current value setting. Press encoder potentiometer to return, and the data will be automatically saved.
1.4.2.8?System Information
System information operation video:
You can press SHIFT + MENU to enter the system setting menu, and then press the right button three times to enter the system information menu as shown above.?You can view the SN number, firmware version and system temperature here.
Android APP Instruction
2.1?Mobile Phone APP?Installation
This App only supports Android 5.0 to Android 10.0 operating system, and there may be incompatibilities problems between APP and operating system,?please install and test the software before buying the product.?It will apply for location service, please agree and turn on the location service. After downloading the mobile APP zip-file, please install the APP in file manager.?Don't install or remove Wi-Fi module when the powered?on, otherwise?it will be damaged.?This instruction is made for version 1.1.2, there will be little difference between different versions, and we do recommend you to download the latest APP?for better experience.
2.1.1?APP?Download
You can download the APP in Google Play by searching RDPower.
You can also download the RD60XX?APP zip-file in this URL:
2.2?Installation Introduction
After the installation, you can see the icon as shown below:
2.2.1?APP?Update
Click the APP icon, After the APP starts, it will automatically detect whether there is a new?version, and it will remind you by popping the window.?You need to check if there is a new version by manual detecting.
2.2.2?APP Interface Display
When finish the installation and succeed in connection, it will show the main page as shown in the right picture.
BN:?call out/ shut down sidebar | CB:?set?button |
BO:?connection button | CC:?keypad lock indication |
BP:?export data to mobile phone folder | CD:?protection status indication |
BQ:?data curve | CE:?constant voltage/ constant current status |
BR:?actual output current | CF: screen brightness |
BS:?actual output voltage | CG: system temperature |
BT: actual output power | CH: data group quick call out |
BU:?input voltage | CI: battery voltage |
BV:?preset voltage value | CJ: external sensor temperature detecting value |
BW:?preset current value | CK: accumulated output power |
BX:?ON/OFF button | CL: accumulated output capacity |
BY:?setting wheel | CM: model being connected |
BZ:?move the cursor to the left | CN: product SN number |
CA:?move the cursor to the right | CO: product firmware version |
2.2.3?APP?Operation
2.2.3.1?Network Distribution
|
|
Picture 3 | Picture 4 |
| |
Picture 5 | Picture 6 |
| |
Picture 7 | Picture 8 |
Connect Wi-Fi for the first time, please insert the WiFi board to the right place, then power on RD6012, you will see the blue LED blinks once. Set the communication interface to WIFI, restart RD6012, then place the RD6012?and the mobile phone close to the 2.4G router (the mobile phone must also be under the same 2.4G network, and the router must disable the AP isolation function?and the WMM function).
RD6012?will wait for the phone to connect as shown in Picture 3. Press?"BN"?to call out the sidebar, clicks on the?"Network distribution"?as shown in Picture 5, then enter the WiFi password and confirm you are using 2.4G network as shown in Picture 6. After 10 seconds, the RD6012?will obtain the IP address of the mobile phone as shown in Picture 4. Then click "Next", fill in the WIFI password as shown in Picture 7, click "CONFIRM" below, wait for about 20s, it will show success as shown in Picture 8, then RD6012?will automatically restart, the distribution network is successful, return to the main interface and click?"BO"(Connection). If the distribution network fails, please power off the module and re-operate in the same way (multiple networking failures you can?watch the video and?try to use the hotspot of the mobile phone to test).?If you use Huawei?brand phone, please turn off the random MAC address function.
3.2.3.2?Proper Wi-Fi Connection
Android APP download and connection operation video:
When power on RD6012, it will connect Wi-Fi first, and then detect if it can be connected to APP, and it may not be connected?successfully if the phone is under screen-lock status or the APP is running at the background. If the IP address of the phone has changed, you need to press the "left direction" button and then press "ENTER" button to reset the net, repeat 3.2.3.1 operation.
2.2.3.3 APP Operation
Android APP operation video:?.
Click?"BV"?to set the output voltage, and use the wheel?"BY"?to adjust the value, the?"BZ",?"CA"?to change the position of cursor, click?"CB"?to set the parameter. Click?"BP"?to exports the voltage-current curve to excel file, up to 24 hours document can be recorded.
NOTE:
There are many kinds of Android phone, so the user interfaces maybe different on some brand phones or different scales of the same brand.
Application permission requirements, allow the necessary permissions when the APP is installed (allow background running, using Bluetooth, operation on the folder, reading the application list, etc.) and also set the permissions of the APP after installation: Allow background running, never shut down when lock screen, allow self-starting (it is used to prevent the system from forcibly exiting the APP when recording data), etc.
IOS APP Instruction
3.1?Mobile Phone APP?Installation
3.1.1?APP?Download
IOS APP can only supports IOS10.0-13.4?system, please search "RDPower" in the APP store to download, or search "RD6006"?to find the APP,and there may be incompatibilities problems between APP and operating system.The software opened under IOS13 will apply for location service for the first time. Please agree and open the location in Settings-Privacy.?Don't install or remove Wi-Fi module when the power is on, or else it will be damaged. This instruction is made for version 1.0.1, there will be little difference between different versions, we do recommend you to download the latest App for better experience.
3.2?Installation and Operation
IOS APP download and connection operation video :
You can see the APP icon (as shown on the right) when finished the installation.
The first time you start the APP, there will be prompt as shown in Picture 10?if your mobile phone system is IOS13 or above, choose "Allow when using APP", if your system is under IOS13, you can see the prompt as shown in Picture 11, please choose "Wireless LAN and cellular mobile network".
3.2.1?APP?Update
You can download the latest the software at APP store, this instruction is corresponding to IOS APP version 1.0.9.
3.2.2 UI Instruction
?????You can see the user interface as shown in Picture 9.
AN:?connection button | BA:?system temperature |
AO:?export data to mobile phone folder | BB:?data group |
AP:?data curve | BC:?screen brightness |
AQ:?actual output voltage | BD:?battery voltage |
AR:?actual output current | BE:?external sensor temperature detecting value |
AS:?actual output power | BF: accumulated output power |
AT: preset voltage value | BG: accumulated output capacity |
AU:?preset current value | BH: model being connected |
AV:?output ON/OFF button | BI: product firmware version |
AW:?protection status indication | BJ: product SN number |
AX:?battery status indication | BK: main page |
AY:?constant voltage/ constant current status | BL: network distribution?page |
AZ:?input voltage?measurement value | BM: personal center |
3.2.3 APP Operation
3.2.3.1?Network Distribution
|
|
Picture 9 | Picture 10 |
|
|
Picture 11 | Picture 12 |
|
|
Picture 13 | Picture 14 |
Connect Wi-Fi for the first time, please insert the WiFi board to the right place, then power on RD6012, you will see the blue LED blinks once. Set the communication interface to WIFI, restart RD6012, then place the RD6012?and the mobile phone close to the 2.4G router (the mobile phone must also be under the same 2.4G network, and the router must disable the AP isolation function?and the WMM function).
RD6012?will wait for the phone to connect as shown in Picture 13. Press?"BL"?to jump to the network distribution page and enter the password. Click "Initialization"?and wait about 20 seconds, RD6012?will obtain the IP address of the mobile phone as shown in Picture 14. Then click "Configure Network", wait about 30s, it will show success on the APP, then RD6012?will start normally, the distribution network is successful, return to the main interface and click?"AN"(Connection). If the distribution network fails, please power off the module and re-operate in the same way (multiple networking failures you can?watch the video and?try to use the hotspot of the mobile phone to test).
3.2.3.2?Proper Wi-Fi Connection
When power on RD6012, it will connect Wi-Fi first, and then detect if it can be connected to APP, and it may not be connected?successfully if the phone is under screen-lock status or the APP is running at the background. If the IP address of the phone has changed, you need to press the "left direction" button and then press "ENTER" button to reset the net, repeat 2.2.3.1 operation.
3.2.3.3 APP Operation
IOS?APP operation video:?.
?Click?"AT"?/ "AU"?text label and enter the value?to set the output voltage/ output current, then click at the blank area to return, if you enter a value exceeds the limit, it cannot be applied. Click?"AO"?to exports the voltage-current curve to excel file, up to 24 hours document can be recorded.
?????Click the personal center to set the software language or get help to use the APP.
PC Software Installation and Operation Instruction
Requirement: Win 7-Win10 system and the computer has Internet connection.
This PC software is designed by Hangzhou Ruideng technology CO., LTD, it has no virus, if your anti-virus software prompts for a virus warning, please allow all its features, otherwise it will affect the normal operation of the software.?PC software supports Win7-Win10 system, and there may be?incompatibilities problems, if you really need it, please install and test the software before buying the product.?This instruction is made for version 1.0.0.8, there will be little difference between different versions, and we do recommend you to download the latest App for better experience.
RD6018?digital power supply file download link:
4.1 Software Download
PC software download and basic operation video:
4.1.1 Unzip Files
The first time you use this software, you need to install the driver program first, you need to click CH341SER to install the driver, the insert a Micro USB cable into RD6006/RD6012/RD6018 and wait for the?computer to install the driver.
4.1.2 Unzip Files
Unzip the file to Disk(D) of the PC. You need to run Net framework4.7.2.exe to install the .Net environment, then click RidenPowerSupply.exe?directly to use the software, please do not delete any files.
4.2 Software Operation
4.2.1 Software Connection
Double click?RidenPowerSupply.exe?to run?the PC software.
WiFi connection is a test function, due to poor compatibility with?some computers, if you cannot connect PC software via WiFi, please ignore this function. For this function, we do not provide any guarantee and technical support,?and we will decide whether to keep this function based on customer feedback.
WiFi connection video link:?
Click WiFi on the PC software and enter the WiFi name and password, set the communication interface to WIFI and reboot, you can see the display of RD6018 as shown in picture 15, and click "WiFi Network" to distribute network, wait RD6018 display as shown in picture 16(wait 1-5 seconds), click "NEXT", wait for a while?(about 20 seconds), the PC software shows connection successful, then click "Connect" to communicate.
USB connection: Set RD6018 communication interface to USB and connect RD6018 and PC, the PC software prompts the serial port has been updated and clicks online.
4.2.2?PC Software Operation Instruction
Choose the right communication port, baud rate, slave address?(default 001), click?"CONNECT"?to start communication. If the communication succeeds, the power supply button will be locked automatically, the buttons will automatically unlock after 3 seconds of accidental disconnection, and the?"CONNECT"?turns to?"DISCONNECT"; Click?"ON"?to turn on the output of the power supply, and it will turn to?"OFF".
4.3?Functions Introduction
The PC software interface mainly has basic functions, firmware upgrade, Logo upgrade, version update detection and language setting...
CP:?Voltage-Current Curve | DA:?System Temperature(¡É) |
CQ:?Battery information/ Data Group Quick Call Out | DB: System Temperature(¢µ) |
CR:?Calibration | DC:?Constant Voltage/ Constant Current Status |
CS: RD/DPS series switch | DD:?Protection Status Indication |
CT:?Language | DE:?Screen Brightness Setting |
CU: Software Update | DF:?Synchronize System Time |
CV: About | DG:?Output Current Preset value |
CW: Input voltage | DH: Output Voltage?Preset value |
CX: Actual Output Voltage | DI:?Firmware Version |
CY: Actual Output Current | DJ:?Serial Number |
CZ: Actual Output Power | DK: Product Model |
4.3.1 Basic Functions
PC software operation video:?
The basic functions of PC software: voltage/current preset, data group quick call out, calibration fine tuning, brightness setting, voltage and current curve exporting. You can rotate the wheel or enter the value?to set the voltage and current, the graph above the button shows the real-time voltage and current curve.?You can zoom in and out the curve by using the mouse wheel, double click the curve to auto adjusts?the axis, you can right click on the curve to clean the curve or export the curve data to picture or excel.
4.3.2?Calibration
The calibration fine-tuning function needs to be operated by a professional electronic person who has more than five and a half multimeter. It will change the system setting, incorrect operation may exceeds?the hardware limit and cause damage, and the resulting damage is not covered by the warranty! The limit error of the product is generally much smaller than the nominal error, when the error is close to or even higher than the nominal error, you need to check if the measuring instrument is accurate.
RD6006 calibration operation video:?
Click?"Calibration"?and enter the password "168168", you can enter the Calibration Fine Tuning page?(if you enter the password, by default you have accepted the above red letter agreement).?It can read the calibration data after connection; click the arrow to fine tuning the data. According to the linear function y=kx+b, the constant b is equivalent to the zero value, the slope k is equivalent to the proportional value, adjust this two values so that the data will be close to the real test value.
Set the output voltage at 1V, adjust the output voltage zero point to make the multimeter display close to 1V, and then set the output voltage at 30V, adjust the output voltage proportional value to make the multimeter display close to 30V. In the same way you can set 0.1A and 3A output current to calibrate the zero point and proportional value of the output current.
Set the output voltage at 1V and calibrate the actual output voltage zero point to make the actual output voltage displayed on RD6012?close to the value on multimeter. You can set 30V and calibrate the proportional value of actual output voltage. In the same way you can set 0.1A and 3A to calibrate the zero point and proportional value of the actual output current.?(This section does not provide technical support. If you do not understand, please check the related information).
4.3.3Advanced Function
You can set the output voltage and current by chart in the advanced function page, you can set every step between 1 and 9999 seconds, you can set 200 steps max, it can output automatically or manually. You cannot choose other operation page when it performs programming output or other operations, you can only switch other page when it ends.
4.3.4RS485 Multiple Devices Communication
4.3.5 Firmware Update
Firmware update operation video:?
Press and hold "ENTER" and power on RD6018, enter the boot mode, then connect it to computer, there will be "boot mode" in the mode information text box, then click?"Firmware Update", a firmware update?prompt will pop up on the interface, and click "Now" to upgrade. (You can update?the firmware under the normal?mode, if it cannot be started up normally, you should press and hold the?"ENTER"?button and power on, update?it under boot mode.?It doesn't support firmware update under WiFi connection mode).??
During the firmware upgrade process, the interface is displayed as follows:
4.3.6Boot Logo Update
Boot logo setting video:
Click?"Start?LogoUpdate", a Logo upgrade prompt will pop up on the page, please select a picture with a size of 320x240 and a resolution of 96dpi. Some logo samples can be used in the installation package.
Click "Picture Import" and RD6018 will reboot automatically.
4.3.7?Version Update Detection
Click?"Software Update",?the software will automatically detect if there is a new version, if so, an update prompt will pop up on the interface.
4.3.8?Language Setting
Click?"Language", a language setting prompt will pop up on the interface, you can choose Simplified Chinese, English, France and German.
4.3.9 About