![](https://ae01.alicdn.com/kf/Hb4ef57161790491bbfb8536009662b43e/0-200V-DC-0-300A.jpg) ![](https://ae01.alicdn.com/kf/H029de3b9f1ab427b805991453525537ce/0-200V-DC-0-300A.jpg) ![](https://ae01.alicdn.com/kf/H434d9fe70ca94510b5eefe2d4a0af602n/0-200V-DC-0-300A.jpg) ![](https://ae01.alicdn.com/kf/H74963cfa2dc94e68989cfeecf15782ebJ/0-200V-DC-0-300A.jpg) aHR0cDovL2ZyZWVzaGlwLmNvLmty![](https://ae01.alicdn.com/kf/Hb4ef57161790491bbfb8536009662b43e/0-200V-DC-0-300A.jpg) ![](https://ae01.alicdn.com/kf/H029de3b9f1ab427b805991453525537ce/0-200V-DC-0-300A.jpg) ![](https://ae01.alicdn.com/kf/H434d9fe70ca94510b5eefe2d4a0af602n/0-200V-DC-0-300A.jpg) ![](https://ae01.alicdn.com/kf/H74963cfa2dc94e68989cfeecf15782ebJ/0-200V-DC-0-300A.jpg) ![](https://ae01.alicdn.com/kf/H06f9986792d54ce38db8610301cfaccbb/0-200V-DC-0-300A.jpg)
- Â÷¿ø: 89.6x49.6mm
- ÀÛµ¿ ¿Âµµ: -20~60C
- °ø±Þ Àü¾Ð: 0-200v
- Á¤È®µµ µî±Þ: 1%
- ¸ðµ¨ ¹øÈ£: PZEM-013/015
- ´ëÇü È°ÀÚ: µðÁöÅÐ Àü¿ë
- DIY ¿ëÇ°: ELECTRICAL
- ºê·£µå À̸§: Gaqqee
- ¿ø»êÁö: Áß±¹
- item: Battery Capacity Tester
¿É¼ÇÁ¤º¸[(350850)PZEM013 10A] [(350853)PZEM015 No Shunt] [(10)PZEM015 50A Shunt] [(29)PZEM015 100A Shunt] [(173)PZEM015 200A Shunt] [(175)PZEM015 300A Shunt]
PZEM-013/015 DC multifunction battery tester, this meter is mainly used to test all kinds of battery`s voltage, discharge current, discharge power, discharge impedance, internal resistance, capacity, dump energy,energy consumption and running time, and display the measurement data through LCD screen.
PZEM-013: Measuring Range 10A (Built-in Shunt) PZEM-015: Measuring Range 300A (use external shunt, can matched with 50A, 100A, 200A, 300A four kinds of shunt).
Function description
Voltage Measuring range: 0-200V. (when the test voltage is less than 8V, please use the independent power supply mode) Display format: less than 10V display as: 9.99V less than 100V display as: 99.9V greater than 100V display as: 199V Minimum resolution:0.01V The starting test voltage: 0.05V Measurement accuracy:1%
Current Measuring range: 0-10A. (Type: PZEM-013) 0-300A(Type: PZEM-015) can set 50A, 100A, 200A,300A four range depend on the external shunt, the factory default is 100A. Display format: less than 1A display as: 999mA £¼10A display as: 9.99A £¼100A display as: 99.9A ¡Ã 100A display as: 199A Minimum resolution: 1mA The starting test current: 10mA(Type: PZEM-013) 20mA(Type: PZEM-015) Measurement accuracy:1%
Power Measuring range: 0-2000W (Type: PZEM-013) 0-60000W(Type: PZEM-015). Display format: £¼ 10W display as: 9.99W £¼ 100W display as: 99.9W £¼ 1000W display as: 999W £¼ 10000W display as: 9.99kW ¡Ã 10000W display as: 19.9kw Minimum resolution: 0.01W The starting test power: 0.1W (Type: PZEM-013) 0.2W (Type: PZEM-015) Measurement accuracy:1%
Impedance Impedance=Voltage/ Current Measuring range: 0-1000ohm Display format: £¼ 100ohm display as: 99.9ohm ¡Ã 100ohm display as: 999ohm When over the test range or the current is zero, it display "---" Minimum resolution: 0.1ohm Measurement accuracy:1%
Internal Resistance Internal resistance= (Full voltage - Bring load voltage) / Bring load current, when the bring load voltage is larger than the maximum voltage, the internal resistance is zero. Measuring range: 0-999 milliohm Display format: 999 milliohm , when over the test range or the current is zero, it display "---". Minimum resolution: 1 milliohm Measurement accuracy:1% Note: Before you test the internal resistance, you should preset the full voltage depend on the battery type, after it is fully charged you can use it to test; if you do not fully charge it, you can set the battery without load voltage is the full voltage, then test; the internal resistance is not a fixed value, the more the battery discharged, the bigger the resistance.
Capacity Measuring range: 0-1000AH Display format: £¼ 1AH display as: 999mAH £¼ 10AH display as: 9.99AH £¼ 100AH display as: 99.9AH £¼ 1000AH display as: 999AH Minimum resolution: 1mAH Measurement accuracy:1% Note: Battery capacity testing is a cumulative process of discharge current versus time, it need some time, the time is depend on the discharge current; before you test the capacity, you should preset the full voltage and the cut-off voltage depend on the battery type, after it is fully charged you can use it to the discharge test; When the dump energy display blank, it means the discharge is over, this capacity display value is the battery`s capacity.
Dump energy Dump energy is display via the battery symbol, totally 10 grids, every grid present 10% energy. Dump energy is calculated via the current battery voltage value, before test you should preset the full voltage and the cut-off voltage depend on the battery type; every grid voltage = (the highest voltage - the lowest voltage) / 10.
Accumulate energy consumption Measuring range: 0-9999kWh Display format: £¼ 1kWh display as: 999Wh £¼ 10kWh display as: 9.99kWh £¼ 100kWh display as: 99.99kWh £¼ 1000kWh display as: 999.99kWh ¡Ã 1000kWh display as: 9999kWh Over the test range will become zero. Minimum resolution: 1Wh Measurement accuracy:1% Note: 1Wh=0.001kWh=0.001 Kilowatt
Running time Measuring range: 0 ~ 999 hour (without load the time will not accumulate) Display format: 0:00:00 ~ 999:59:59 Over the test range will become zero.
Operating Instructions Setting the full and cur-off voltage
Package included: 1 * DC Multimeter Battery Tester Monitor
|
|
|
|
|