YF-7 Upgrade AC 220V Dual Channel Delay Relay Module Control Switch 12V 24V Multifunctional Pulse Trigger Cycle Timer 0.01s-999m
Features:
*This delay timing relay has 32 kinds of commonly-used functions to meet the needs of more application.
*Easy to control the operation of electromagnetic valves, pumps, motors, lamp belts and other equipment.
*Output power: It can control DC or AC load within 5A.
*Time control range: 0.01 seconds to 999 minutes can be adjusted at any time.
*High quality electronic components, stable performance.
Specifications:
Model: YF-7
Input voltage: DC5V, DC7~30V, AC220V
Time range: 0.01s -999 minutes(Adjustable)
Weight: 80g
![](https://ae01.alicdn.com/kf/S65a7f2b2f0af4b99b53107fc42aa613dP.jpg)
![](https://ae01.alicdn.com/kf/S1c4ac678c36c452ca917aec1418ecb33R.jpg)
![](https://ae01.alicdn.com/kf/Se9da1aa6073c4bcb995868d007bc8187y.jpg)
![](https://ae01.alicdn.com/kf/S1c507419de5642c7b8277a77cb2482ffS.jpg)
![](https://ae01.alicdn.com/kf/S7ee256939d4c4c78842f7bc772b36b28j.jpg)
![](https://ae01.alicdn.com/kf/S593c9219e2524009aebcf1c67a1efca2T.jpg)
![](https://ae01.alicdn.com/kf/S1f262370123d41d3a920e6a6b72a43621.jpg)
![](https://ae01.alicdn.com/kf/Sebac64b9ba7d4a88b8cbe00fba479f888.jpg)
![](https://ae01.alicdn.com/kf/S4b4c4805809b47eb9693d4cac5c3523aq.jpg)
Package list:
1 * Relay Module
Note:
The actual product color may deviate from the photo due to light.
There may be a slight deviation in the measurement of product.
Wiring port description:
Left 1, + : Input power positiveLeft 2, - : Input power negative
Left 3, signal 1: positive signal input
Left 4, signal 2: positive signal input
Left 5, common line: signal input negative (signal 1 and signal 2 share a negative)
Right 1, normally closed 1: Relay 1 normally closed interface, the relay is suspended before the suction, after the pull-in and short with COM
Right 2, Common 1: Relay 1 common interface
Right 3, normally open 1: Relay 1 normally open interface, shorted to COM before the relay is closed, suspended after suction
Right 4, normally closed 2: Relay 2 normally closed interface, the relay is suspended before the suction, short-circuit with COM after the suction
Right 5, Common 2: Relay 2 common interface
Right 6, normally open 2: Relay2 normally open interface, short-circuit with COM before the relay is pulled in, hang and hang after suction
6: Function list: function can be arbitrarily set to buy back, there are instructions provided; power failure can memorize any parameters set
All the functions in P-11 to P-44 are as follows; signal 1 corresponds to relay 1; signal 2 corresponds to relay 2;
The two channels can be triggered at the same time; they are independent of each other; they do not affect each other; the respective relays of the respective signal tubes
P-11: Jog (give the signal relay, the signal disappears and the relay stops)
P-12: Self-locking (send a signal relay to pull in, then give a signal relay to stop)
P-13: Give the signal, the relay will stop automatically for A seconds; the trigger will be invalid during the delay.
P-14: Give the signal, the relay will stop automatically for A seconds; trigger the retime during the delay.
P-15: Give the signal, the relay will stop automatically for A seconds; trigger the superimposed timing during the delay.
P-16: Give signal, the relay will stop automatically for A seconds; trigger reset during delay
P-17: Give the signal, the relay is closed, the input signal is disconnected, the power is turned off after A seconds, and the signal is kept output again during the delay.
P-18: After power-on, the relay will immediately pull in, after a delay of A seconds, the power will be turned off;
P-21: Give the signal, after a delay of A seconds, the relay pulls in
P-22: Give signal, after more than A seconds, the relay pulls in, the signal disappears, the relay stops.
P-23: After the signal disappears for more than A seconds, the relay pulls in, the signal disappears, and the relay stops.
P-24: There is a signal. After more than A seconds, the relay is closed. When the signal disappears for more than A seconds, the relay stops.
P-25: There is a signal after more than A seconds, the relay is closed, and after a signal exceeds A seconds, the relay stops.
P-26: There is a signal. The relay stops after A seconds of suction. The signal disappears and the relay stops again for A seconds.
P-27: The pulse signal is detected, the relay stops; if there is no pulse signal, the relay delays for A seconds; (the signal is continuous or the signal disappears as no pulse signal)
P-28: After power-on, after a delay of A seconds, the relay pulls in until the power is turned off.
P-31: After power-on, the relay is closed for A seconds, disconnected for B seconds, infinite loop;
P-32: Signal, start P-31 infinite loop; signal disappears, terminate loop
P-33: Give a signal, start P-31 infinite loop; give another signal to terminate the loop
P-34: After power-on, after a delay of A seconds, the relay pulls in and closes after B seconds.
P-35: There is a signal. After a delay of A seconds, the relay pulls in and closes after B seconds.
P-36: There is a signal. After more than A seconds, the relay pulls in, the B is stopped after B seconds, the signal disappears, and the timing is cleared.
P-37: There is a signal, the relay will stop automatically for A seconds, and then stop for 24 seconds. The signal trigger is invalid during A+B time.
P-38: There is a signal, the relay will stop automatically for A seconds, stop and re-time for B seconds, and then automatically close for A seconds.
P-41: There is no signal; the signal disappears; the relay works after the delay of A time.
P-42: The signal disappears, after a delay of A time, the relay works; the end of work B time
P-43: The signal disappears. After the A time, the relay works; the working B time ends.
P-44: After the signal is sent for more than A times, the relay is closed for B seconds.
P-45: After power-on, relay 1 works for A seconds after disconnection; relay 2 works for B seconds.
P-46: Give signal 1, relay 1 works after A seconds is disconnected; relay 2 works for 2 seconds to disconnect
P-47: After signal 1 is applied, relay 1 is operated for A seconds; relay 2 starts to work; after 2 seconds, relays 1 and 2 are disconnected at the same time.
P-48: After power-on, relay 1 works for A seconds after disconnection; stops for B seconds; relay 2 works for C seconds and stops for D seconds;
7: Button setting description: Power-on display "_" means to enter standby mode;
Press the first K1, (It takes more than 1 second to be effective to prevent false triggering) Display: P -11: K2 adjusts the main mode, K3K4 adjustment function
Press the second K1, the screen displays: A00x: K2 and K3 adjust the first time A, K4 adjust the decimal point (time unit)
Press the 3rd K1, the screen displays: b00x: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit)
Press the 4th K1, the screen displays: C00x: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit)
Press the 5th K1, the screen displays: d00x: K2 and K3 adjust the second time B, K4 adjusts the decimal point (time unit)
Pressing K6 for the 6th time, "_" indicates that the setting is completed and enters the standby state.
Press K4 in standby mode to permanently turn off/on the display and switch the low power mode.
![](https://ae01.alicdn.com/kf/Sc90cd76463664f248b9920033540f3c0z.jpg)
![](https://ae01.alicdn.com/kf/S32f97a7da850441f9b899906b980e0d6v.jpg)
![](https://ae01.alicdn.com/kf/S87743517999945adb081a8617d886a35j.jpg)
![](https://ae01.alicdn.com/kf/Se23b8a89777f4400b3a8805154fa7cbds.jpg)
![](https://ae01.alicdn.com/kf/S9f92521015394aaea5521e677e773eb05.jpg)
![](https://ae01.alicdn.com/kf/Sf908be42d3e34631abed22201541862bX.jpg)