DC 12V Trigger Cycle Time Delay Relay LED Three Digital Display Adjustable Timing Relay Control Switch Circuit Timer
Features:
Working voltage: DC12V (normal working voltage DC10V-16V)
Signal source: DC4V~20V (commonly used power supply positive trigger, button, PNP sensor, PLC signal, etc.)
Output capability: can control equipment within DC 30V5A or within AC 220V5A
Quiescent current: 20mA, working current: 50mA
Service life: more than 100,000 times;
Working temperature: -40~85¡É;
Net weight: about 26g
Size: 64.2mm*34.8mm*18.5mm
Description:
Voltage input anti-reverse circuit, worry-free wiring. Signal input optocoupler isolation, strong anti-interference ability. The setting parameters are permanently stored when the power is turned off. Powerful flash MCU online programming function, can contact the manufacturer to customize the required functions according to user needs.
Function Introduction:
P-1: The signal triggers the relay to pull in, the time is up, the relay is disconnected, during the delay period
A: Re-triggering is invalid B: Re-triggering and re-timing C: Re-triggering the relay reset to terminate the timing
P-2: The signal triggers to start the timing time T1, and when the time expires, the relay pull-in time T2 is disconnected (reset)
A: Re-triggering is invalid B: Re-triggering and re-timing C: Start delay without triggering power-on
P-3: Circular use: T1 is turned on, T2 is turned off, infinite loop. For T1 and T2, the time is adjustable; if a certain parameter is turned on or off to 0, the power-on delay is turned on or the power-on delay is turned off without cycling.
A: The relay is turned on immediately after power-on B: The relay is turned off first and then turned on after power-on
P-4: There is a signal, the relay is pulled in, it is kept closed, the signal disappears, the timing is started, the time is up, the relay is disconnected, during the delay period, the signal is given again, the delay is canceled, the relay is held, the signal disappears, and the timing is restarted.
Instructions:
"SET" : Function selection key: Press and hold "SET" for 2 seconds, P-* appears, short press "SET" to select mode, press "Up Key" to enter mode
"Up Key" : Shift key: Press to adjust the flashing position of the nixie tube, which nixie tube flickers, "Down Key"adjust the value of the flickering nixie tube.Until it is pressed "Up Key", the digital tube no longer flashes, the set time is completed, the set time is automatically saved and the memory is powered off.
"Down Key" : When the nixie tube is flashing: "Down Key" adjust the number change, 0 to 9 change in sequence.
When the nixie tube display is normal: "Down Key" adjust the position of the decimal point, the decimal point in the one`s place means 0 to 999 minutes; in the ten`s place, it means 0 to 99.9 seconds; no decimal point means 0 to 999 seconds
Note 1: After the working mode is selected, short press "SET" to switch between A, B, and C of the function. The digital tube will not display A, B or C. You need to press "SET" the signal to trigger the test to know it. The default is A
Note 2: Functions P-2 and P-3 have 2 sets of time to be adjusted. Press "Up Key" six times to form a cycle. The first three times adjust one time, and the last three times adjust another time.
Note:
The relay output is a passive contact, no live output, and controls the on-off function of a line.